Search mode: "AND" "OR"
NEWS ABOUT US MAP IMPRINT CONTACT DISTRIBUTORS DOWNLOADS SITEMAP

SINUS Home
SAMURAI:
What’s new? New Functions Description Developers... Requirements
SAMURAI Options:
Automation Building Acoustics Building Vibration Fractional Octaves HVMA Monitoring Multi Generator Noisecam Video Order Tracking Remote Client Sound Intensity 1 Sound Intensity 2 Sound Power TCP/IP Interface Transfer FRF Vibration Meter Weather Station
 

Field of Application:

In recent years, many new EU guidelines regarding noise emission from machinery have been enacted, e.g. the guidelines 2006/42/EG for machines in general as well as 2000/14/EG for construction machinery and other machines operated outdoors. A sound power declaration is required in order to obtain a CE mark for machines falling within the scope of these guidelines.

The determination of the sound power by means of the sound pressure method according to ISO 3744-46 is the purpose of the SAMURAI option SOUND POWER.

Description:

This option enables the sound power measurement according to ISO 3744-46 with the aid of a 3D diagram which shows the positions of the microphones in relation to the sound source. Depending on the number of available measurement channels, the measurements can be performed simultaneously or sequentially. The software can access several measurement devices in order to increase the number of available measurement channels. Either hemispherical or cuboid microphone deployment geometry may be selected.

The sound power declaration is made in third-octave or octave bands. A clearly laid-out graphical program interface guides the user through the whole measurement procedure.

Technical Data
Standards implemented DIN EN ISO 3744, 3745, 3746
Measurement range 12.5 Hz to 20 kHz
Features
  • Hemispherical or cuboid measurement surface
  • Calculation of microphone positions and display in a 3D diagram
  • Freely selectable measurement sequence
  • Reflecting planes selectable
  • Allowance for reverberation time
  • Evaluation of the K1 and K2 criteria
  • Sound power level declaration in third-octave or octave bands
  • Remote control via network possible
  • Standards integrated:
    ISO 3744:1994(Acoustics -- Determination of sound power levels of noise sources using sound pressure -- Engineering method in an essentially free field over a reflecting plane)
    ISO 3745:2003(Acoustics -- Determination of sound power levels of noise sources using sound pressure -- Precision methods for anechoic and hemi-anechoic rooms)
    ISO 3746:1995(Acoustics -- Determination of sound power levels of noise sources using sound pressure -- Survey method using an enveloping measurement surface over a reflecting plane)



 
Figure 1: Digital photograph of the sound source



Figure 2: Microphone positions



Figure 3: Measurement results from the individual microphone positions



Figure 4: Display of the sound power in third-octave bands